Categories
-
Mechanical & equipment( 64 )
- Jewelry welding machine( 28 )
- Rolling mills machine( 4 )
- Flex shaft machines( 19 )
- Jewelry polishing machine( 31 )
- Jewelry engraving machine( 9 )
- Jewelry melting furnace( 14 )
- Jewelry cleaning machines( 4 )
- Jewelry cutting machines( 2 )
- Jewelry drilling machines( 4 )
- Jewelry plating machine
- Wax injection machines( 4 )
- Ring benders & stretchers
-
Jewelry tools( 20 )
- Testers & measurements( 30 )
- Anvils & bench blocks( 4 )
- Dapping tools & forming( 7 )
- Bench pins, clamps & vises( 8 )
- Metal stamps & punches( 6 )
- Draw plates( 5 )
- Hammer
- Magnifier
- Saws( 8 )
- Scissors( 9 )
- Pliers( 8 )
- Files
- Tweezers( 4 )
- Storage containers( 3 )
- Burs & drills( 7 )
- Wire wrapping & beading( 3 )
- Polishing tools( 26 )
- Grinding tools( 17 )
- Engraving tools( 14 )
- Wax products( 7 )
Custom Services
-
fast transport
EMS, FedEx, UPS, DHL
-
Support 24/7
Online 24 hours
-
Free return
30 Days Free Return
-
payment method
100% Safe Transaction
2L Portable Welding Torch Oxygen Air Conditioning Copper Tube Set
: In stock
$99.99 $129.99
QUESTIONS & ANSWERS
Ask More Wholesale Prices. (100QTY+)
Be the first to ask a question about this.

Usage Notice:
(1) Re-ignition after safety inspection
The firing performance must be checked before using the torch. The method of inspection is to fasten the oxygen hose to the oxygen fitting. After turning on the oxygen, first turn on the acetylene adjustment handwheel, then turn on the oxygen adjustment handwheel, then press the finger on the acetylene joint. If you feel a suction, it indicates that the suction performance is normal. If there is no suction, even if the oxygen flows back from the acetylene joint, it means that the suction performance is not normal and must be repaired, otherwise it is strictly prohibited.
If the suction performance is normal, check for leaks. The inspection method is as follows: connect the acetylene hose to the acetylene joint, immerse the torch in a clean water tank, or apply soapy water to each joint of the welding torch, gas valve, etc., then open the adjusting handwheel, and send oxygen and acetylene. Gas, if there is a tight place, you will find bubbles.
(2) Ignition
After the above inspection is passed, the torch can be ignited. Ignition has two methods: first open acetylene and first open oxygen. In order to ensure safety, it is best to first open acetylene, immediately turn on oxygen after ignition and adjust the flame.
When the high-power torch is ignited, a friction igniter or other special ignition device should be used.
Oxygenation:
1. Connect the large oxygen bottle (oxygen source) and small oxygen bottle with the original oxygen bridge of this product, and fasten the nut;
2. First turn off the low pressure knob of the small oxygen bottle and open the high voltage switch of the small oxygen bottle;
3. Slowly open the switch of the large oxygen cylinder. When the air is blown, there is a slight sound of the wire. When the sound disappears, it indicates that the pressure of the two bottles is balanced and the oxygen is completed.
4. Turn off the switch of the large oxygen cylinder and the small oxygen cylinder, and lower the oxygen bridge;
Note:Note: The oxygen source pressure should not be higher than the working pressure of the small oxygen bottle; the temperature of the small oxygen bottle will increase slightly when oxygen is taken, which is a normal physical phenomenon!
Note: The oxygen source pressure should not be higher than the working pressure of the small oxygen bottle; the temperature of the small oxygen bottle will increase slightly when oxygen is taken, which is a normal physical phenomenon!
Gas bottle gas:
Butane gas flushing method: After shaking the butane gas cylinder, insert the special gas-filling interface of butane gas vertically, and the pointer shows that the butane gas cylinder can be directly dialed after the flushing;
Note: The gas bottle is used for the first time. Because there is air in the bottle, after the gas is flushed, the gas bottle is placed upright, the switch is opened to release the internal air, and the gas is flushed in!
Precautions:
1. The operator must hold the welder operation certificate issued by the national labor department, and the undocumented operation produces adverse consequences, and is responsible for it!
2. The oxygen cylinder is inspected once every three years, and the gas cylinder is inspected once a year, and the full-time inspection unit at the location of the user is responsible for inspection;
3, gas bottles, oxygen bottles should be kept away from fire sources, avoid high temperature sunshine, the surrounding temperature should not exceed 50 degrees Celsius; it is strictly prohibited to use hard objects, heavy objects to knock, hit oxygen cylinders and gas bottles, avoid heat storage, be careful!
4. The gas cylinder inflation amount shall not exceed 1/2 of the gas cylinder volume;
5. The oxygen in the oxygen cylinder cannot be completely used up. The residual pressure of 0.5Mpa must be retained!
6. The failure of the oxygen meter must be repaired and replaced by a professional, and others must not disassemble it!
7. Gas bottles and oxygen cylinders must not be mixed with other gases. Do not contaminate oil!
8, welding torch, dry fire fire extinguisher and other related main parts, must carefully check the function and performance before each use.
9. If you violate the above matters, you will be conceited at your own risk!
Weight: 6.1Kg Size:410*250*120mm
Note: The oxygen source pressure should not be higher than the working pressure of the small oxygen bottle; the temperature of the small oxygen bottle will increase slightly when oxygen is taken, which is a normal physical phenomenon!
Shipping Policy
Shipping cost is charged by the shipping agency according to the destination, the weight and the shipping method.Delivery time depends on the destination and the shipping method you choose. Phyhoo offers the following shipping methods to ensure the safe delivery of your package
- FedEx, DHL and UPS are the fastest delivery methods available. Delivery time is 3 ~ 7 days to all major destinations. Products weighing more than or equal to 2KG will be shipped by FedEx, DHL and UPS by default.
According to your shopping cart, the system will automatically choose the most economical way for you from DHL, UPS and FedEx. - EMS will take 7~21 working days to arrive. Products weighing less than 2K can choose this shipping method.
Orders are processed and delivered Monday-Saturday (excluding public holidays)
Tip: Phyhoo is not responsible for the shipping delay that caused by the severe weather, such as stormy snow or other causes that beyond our control.
30 Days Free returns
We are proud to guarantee 100% satisfaction with all items you purchased on phyhootool.com. If there is any dissatisfaction with your purchase for any reason, full refunding, Unconditional Return and 100% Exchange could be accepted within 30 days from the date of delivery.